      Modern MRI scanners have a wide bore to accommodate obese patients and reduce claustrophobia. In order to enable a wide bore construction, it is common practice to completely redesign the magnet. However in most cases, the most important specification - magnet homogeneity - is compromised. For the Vantage Titan, Canon (former Toshiba) kept the magnet of the Vantage version that has a 60cm bore, but redesigned the gradient coil, maintaining the original magnet specifications. The result is a wide bore system without any compromise to image quality.

       
       

      Extraordinary Patient Comfort:

      • Short 149cm bore
      • 71 cm patient opening
      • Feet-first positioning from neck and below
      • 30dB acoustic noise reduction
      • 43cm low patient couch
      • Light and flexible patient coils
      • Space for every patient
      • > 30cm nose-bore clearance

       


       

      Extraordinary User Comfort:

      • Quiet work environment
      • Easier patient access
      • Simpler patient positioning
      • Reduced installation work (no need for acoustic noise measures)
      • Integrated armrests for easy needle application
      • Infusion stand mounted on the gantry

       

    • Vantage Titan Sets New Standards In Comfort, Imaging And Productivity
      Vantage Titan Sets New Standards In Comfort, Imaging And Productivity
      • Magnetic Field Homogeneity: B0
      While conventional MR systems offer a spherical homogeneous area centered at the isocenter of the scanner, the Titan offers an elliptical-shaped sphere with a scan field of 55cmx 55cmx 50cm homogeneous field of view.
       
       
       
    • State-Of-The-Art Imaging Techniques
      Unique Sequences:
       
      Non-contrast MRA Techniques:
      • Fresh Blood Imaging (FBI)
      • Flow Spoiled FBI
      • Time-SLIP
      • Time-Space Angiography
      • FSBB: Flow Sensitive Black Blood, flow sensitive susceptibility weighted imaging
      • Body diffusion
      • mVOX: 3D isotropic acquisition for brain and body examinations
      • JET: Radial k-Space filling technique for motion correction
      • SPEEDER: Sense-based parallel imaging technique

       


       

      Optimized FAT Suppression Techniques:
      • MSOFT: Slice-selective FAT suppression technique
      • PASTA: Water-selective slice excitation
      • WET: Volume-selective Water Excitation Technique
      • STIR: Inversion Recovery
      • FAIR: Adiabatic FAT suppression
      • Chemical shift selective FAT suppression

       

    • Vantage Titan Sets New Standards In Workflow
      Vantage Titan Sets New Standards In Workflow

      Key Features:

      • Higher SNR
      • High density of coil elements in the FOV (up to 32)
      • High speed-up factors
      • A total of 128 simultaneously connected coil elements
      • Optimal for whole body imaging
      • Automatic coil selection
      • Light coils (comfort for both patient and operator)
      • Universal coils
      • Significantly reduces the need for coil exchange
      • 32 element sliding spine coil integrated to the table
      • Ideal for feet-first imaging
    • EasyTech – Fully Automated Scan Plan

      Reproducibility of scan planes is often compromised through variation in scan plan by the technician operating the scanner. The EasyTech technology addresses this issue. Based on a standard axial scan, the scanner looks for anatomical landmarks and based on these landmarks, it adjusts the scan plan to the appropriate planes. This technology eliminates different orientations in follow-up scans and differences in orientation between patients.

       
       

      NeuroLINE:

      • Anatomical landmark-oriented calculation
      • Six planes can be set
      • Median sagittal plane
      • Horizontal axial plane
      • Coronal plane
      • 3 user-defined planes

       


       

      CardioLINE:

      • Anatomical landmark-oriented calculation
      • SCMR recommended planes
      • Vertical long axis
      • Horizontal long axis
      • Short axis
      • Three-chamber view
      • Two-chamber view
      • Four-chamber view

       

       

    • M-POWER – Workflow-Oriented Software, Optimized For Your Needs
      M-POWER – Workflow-Oriented Software, Optimized For Your Needs

      The M-Power software streamlines your workflow: As soon as a patient is registered in the RIS/HIS including the type of examination, the MRI scanner automatically selects the appropriate protocol that corresponds with the clinical request. In this protocol, the scan parameters as well as the post-processing functions are defined.

       

      • Multimodality platform, minimal interaction, vast possibilities
      • Optimized workflow for routine examinations: fewer clicks, shorter mouse movements
      • Automated post-processing for complex analyses
      • 1-2-3-done! This Toshiba approach ensures that even complex analyses are completed within seconds. Advanced users can further optimize the parameters to achieve even better results.

       


      • Registration

       


       

      • Examination

       


      • Processing/Viewing

       


      • Archiving

       

    • No Waste Of Time
      No Waste Of Time

      In conventional MR systems, anatomy-specific coils could not coexist on the table. Consequently, frequent coil exchange made the process tedious and cumbersome to the operators. Therefore, procedure set-up and patient throughput was inefficient.

       

      With the Atlas coil concept whereby the head, spine and body coils are seamlessly combined, boundary-free image acquisition can be performed while dramatically reducing coil exchange time. This results in an improved workflow.

       

    • Innovative ATLAS Matrix Coil Concept
      Innovative ATLAS Matrix Coil Concept

      With the Atlas matrix coil concept, the number of coil elements and number of receiver channels are optimized with the maximum scan FoV. A 50cm longitudinal scan FoV can incorporate 32 elements which can be fed to a 16-channel receiver system for improved SNR or to a 32-channel received system for high parallel imaging factors.

       
       

      Easy Coil Handling:

      • Sliding spine coil, integrated in the couch top
      • Light-weight, flexible body coil (up to 3 parallel coils)
      • Splitable head coil with optimized attachments

       

       

      Versatile Coil Combinations:

      • Automatic coils selection (AS compass)
      • 9 coil connectors on the couch

       

       

      High SPEEDER Factors:

      • Up to 32 elements in the FoV

       

       

      Multisized Elements:

      • Anatomically optimized elements
      • Small center elements for high resolution
      • Large peripheral elements for high sensitivity

       

       

    • OCTAVE Matrix Coil Concept

      Based on the innovative Atlas matrix coil concept, Canon (former Toshiba) developed an economic version using the similar conceptual matrix design approach. This became the Octave matrix coil concept in which the number of elements was reduced without compromising image quality. For body imaging, the Octave spine coil can be combined with the 4-channel Flex coil or with the Atlas body coil for larger coverage.

       
       

      Octave SPEEDER Head/Neck Coil:

      • 11 elements
      • 22cm inner diameter
      • Tiltable with optional wedge

       

      Octave SPEEDER Spine Coil:

      • Sliding spine coil, integrated in the couchtop
      • 12 elements
      • 47cmx 78cm
      • 120cm scanable range for CTL spine when combined with the Octave head coil

       

    • Orthopedic Multi-Channel SPEEDER Coils

      Shoulder Coil:

      • 6 channels
      • semi-flexible
      • comfortable patient position
      • Can also be used for knee, elbow, and ankle

       


       

      Knee Coil:

      • 8 channels
      • 18cm inner diameter
      • lateral sliding mechanism
      • upper part can be removed

       


       

      Hand/Wrist Coil:

      • 12 elements
      • 6 channels
      • hand and wrist mode
      • ­lateral or isocentric position
      • foldable

       


       

      XL-Knee Coil:

      • 6 channels
      • transmit/receive coil
      • 22cm inner ­diameter
      • lateral sliding mechanism
      • upper part can be removed
      • can also be used for pediatrics

       

    • General Purpose FLEX Coils

      16-Channel Flex Medium Coil:

      • Omni-directional
      • flexible
      • comfortable patient positioning
      • 24cmx 40cm wrap

       


       

      16-Channel Flex Large Coil:

      • Omni-directional
      • flexible
      • comfortable patient positioning
      • 24cmx 70cm wrap

       


       

      32-Channel Pediatric Cradle:

      • Two Flex medium coils combined in a pediatric support for very detailed infant examinations.

       


       

      4-Channel Flex Coil:

      • Omni-directional
      • flexible
      • comfortable patient positioning
      • 23cmx 52cm wrap

    • MR Mammography

      8-Channel Breast SPEEDER Coil:

      • 8 channels
      • can be equipped with biopsy tools
      • extra large access for biopsies
      • coil elements can be individually positioned

       


       

      mBreast Package:

      • Dynamic contrast-enhanced ­examinations
      • diffusion measurements
      • silicone imaging ­combined with the DRKS package also 3D-FFE keyhole imaging
      • time-intensity curves

    • MR Cardio

      When the MRI scanner is equipped with 32 receiver channels, the 32-element cardiac coil can be used. With the small octagonal ­elements, it is a very high density coil enabling the use of high SPEEDER factors, improving temporal resolution.

       

       

      32-ch Cardiac Coil:

      • High resolution
      • High density
      • 34cmx 44cm
      • Light-weight

       


       

      mCardiac Package:

      • CINE studies
      • Realtime CINE studies
      • First-pass during rest and stress
      • Late enhancement (2D and 3D)
      • Echo-Navigator coronary angio

       


       

      CAAS Package:

      • Cardiac analysis
      • EF, SV, SVI, CO &CI
      • ED & ES volume calculation
      • Body surface area
      • Volume over time
      • Wall motion
      • Cine display
      • Cardiac perfusion
      • Delayed enhancement analysis